From owner-chemistry- at -ccl.net Wed Mar 8 09:56:01 2006 From: "Pablo Vitoria pablo.vitoria]![ehu.es" To: CCL Subject: CCL:G: RI DFT approximation in G03 Message-Id: <-31147-060308095401-27038-763Fwc+5a3NIk5Ahf+FWzQ[*]server.ccl.net> X-Original-From: "Pablo Vitoria" Content-Transfer-Encoding: 7bit Content-Type: text/plain; format=flowed; charset="iso-8859-1"; reply-type=original Date: Wed, 8 Mar 2006 15:53:45 +0100 MIME-Version: 1.0 Sent to CCL by: "Pablo Vitoria" [pablo.vitoria%%ehu.es] Dear Stefan, Thank you very much for your e-mail, which happens to be the first answer to my question. After sending the message to CCL I did some more testing, and I am quite sure that the problem happens with the normalization of the auxiliary density-fitting basis set, which G03 does wrong, probably a bug as you say since the other programs (ORCA, NWChem, ...) do it right. I asked Gaussian, Inc. about this but no answer yet. Thanks again Regards Pablo ----- Original Message ----- > From: "Stefan Grimme grimmes..uni-muenster.de" To: "Vitoria, Pablo " Sent: Wednesday, March 08, 2006 3:31 PM Subject: CCL:G: RI DFT approximation in G03 > Sent to CCL by: Stefan Grimme [grimmes---uni-muenster.de] > > Dear Pablo, > for acetone PBE/SV(P) I get a RI-non-RI difference of > 0.6 mEh with TURBOMOLE (old Coulomb aux-basis). > Some time ago I did a RI-test with G03 that also produced a very, very big > difference of some hundreds of mEh, so to me that sounds like a program > bug. > Regards > Stefan > ____________________________________________________________ > Prof. Dr. Stefan Grimme > Organisch-Chemisches Institut (Abt. Theoretische Chemie) > Westfaelische Wilhelms-Universitaet, Corrensstrasse 40 > D-48149 Muenster, Tel (+49)-251-83 36512/33241/36515(Fax) > Email:grimmes|a|uni-muenster.de > http://www.uni-muenster.de/Chemie/OC/research/grimme/ > ____________________________________________________________> >