Re: CCL:CCL



 Rick Venable wrote:
 
 For a solvated protein simulation, I'd monitor the potential energy, the
 radius of gyration, and the bacbone RMSD relative to the starting
 structure.  When all 3 of these become flat, one could argue that
 the system is equilibrated; this could require 100s of picoseconds.
 
 Although indeed one can argue this, it is hard to tell what 'flat' means
 in a practical sense. For a seond-year lecture I give I have three slides
 each giving the rmsd of a protein w/r to the x-ray structure. All three
 of them level off to a nice plateau at the end, and appear to be genuinly
 equilibrated in the way you define that. But, the three plots are of the
 same simulation, the first of 0-100ps, the second of 0-1ns, and the last
 of 0-10ns! If you overlay them, they are almost the same, except for the
 scale of the axes! Those of you who'd like to see them, please ask me and
 I can send you the three jpg files (~50k each).
 While I don't regularly monitor r_gyr or e_pot, I don't know but suspect
 that they would show similar behaviour... (although they may equilibrate
 much faster than the rmsd).
 --
 Groetjes,
 Anton
  _____________ _______________________________________________________
 |             |                                                       |
 |  _   _  ___,| K. Anton Feenstra                                     |
 | / \ / \'| | | Dept. of Pharmacochem. - Vrije Universiteit Amsterdam |
 |(   |   )| | | De Boelelaan 1083 - 1081 HV Amsterdam - Netherlands   |
 | \_/ \_/ | | | Tel: +31 20 44 47608 - Fax: +31 20 44 47610           |
 |             | Feenstra.-at-.chem.vu.nl - www.chem.vu.nl/~feenstra/       |
 |             | "If You See Me Getting High, Knock Me Down"
 |
 |             | (Red Hot Chili Peppers)                               |
 |_____________|_______________________________________________________|