Re: CCL:how to print Fock matrix in Gaussian



Hi,

The SCF equations are resolved in link 402 when using semi empirical methods. You thus
have to use the iop 4/33 to print more informations than usual.
To get the Fock matrix in a lower triangular form, just add "iop(4/33=4)" in your command line.
Please note that this will give you the desired information for each SCF iteration.

I hope this will help you,

Yohann
 

jz7/at/duke.edu wrote:

Dear all,

How should I write the command line to print the Fock matrix using INDO
method in Gaussian (just a single point calculation)?

Thanks a lot!