| Dear Sir, This problem is due to error in termination the final steps of optimization. There are two solutions for your problem: 1- Take the xyz coordinate from the standard orientation from output file then put it in molecular specification then run your calculation. Or 2- Another way, restart your calculation from check point file and add these keywords: GDIIS, NOEIGEN, XQC. My regards ************************************************************************************************** Morad M.
El-Hendawy, IRELAND ************************************************************************************************** If you want a happy life, do four
things: 1- Contemplate and be thankful, 2- The past is gone forever, 3- Today all that you have, 4- Leave the future alone untill it come. ******************************************************************************************************************* --- On Sat, 9/5/09, veronica ferraresi veroferraresi[]gmail.com <owner-chemistry/./ccl.net> wrote:
|