From chemistry-request@server.ccl.net Thu Mar  6 11:41:48 2003
Received: from evans.univer.kharkov.ua ([80.92.225.132])
	by server.ccl.net (8.11.6/8.11.0) with ESMTP id h26Geca19608
	for <Chemistry@ccl.net>; Thu, 6 Mar 2003 11:40:41 -0500
Received: from spin.univer.kharkov.ua (spin.univer.kharkov.ua [192.168.213.252])
	by evans.univer.kharkov.ua (8.12.6/8.12.5) with SMTP id h26GeAfS029511;
	Thu, 6 Mar 2003 18:40:15 +0200
Received: by spin.univer.kharkov.ua with Microsoft Mail
	id <01C2E40F.3D79F3C0@spin.univer.kharkov.ua>; Thu, 6 Mar 2003 18:36:02 +0200
Message-ID: <01C2E40F.3D79F3C0@spin.univer.kharkov.ua>
From: "sergey i. kotelevskii" <kotelevskiy@univer.kharkov.ua>
To: "'p smith'" <p.smith@student.umist.ac.uk>,
   "'CCL community'"
	 <Chemistry@ccl.net>
Subject: RE: infra-red stretching frequencies
Date: Thu, 6 Mar 2003 18:36:01 +0200
MIME-Version: 1.0
Content-Type: text/plain; charset="us-ascii"
Content-Transfer-Encoding: 8bit
X-MIME-Autoconverted: from quoted-printable to 8bit by server.ccl.net id h26Gfma19629



----------
From: 	p smith
Sent: 	Friday, February 28, 2003 3:10 AM
To: 	chemistry@ccl.net
Subject: 	CCL:infra-red stretching frequencies

Hello,

	It depends. That is, the cheapest/reliable method depends on the system under study. For qualitative purposes on large stable systems, you may use AM1 or PM3 frequencies scaling them heavily above ~ 1500-2000 cm(-1). However, you couldn't expect  reliability e.g. from Hydrogen-bonded complexes in low-frequency region. As the cheapest universal tool, DFT B3LYP is recommended, with mandatory polarization functions on heavy atoms (and hydrogens for X-H stretch).
	Also take a look at:

A.P.Scott and L. Radom, "Harmonic Vibrational Frequencies: An Evaluation of Hartree-Fock, Moller-Plesset, Quadratic Configurational Interaction, Density Functional Theory, and Semiempirical Scale Factors", J. Phys. Chem. 1996, V.100, 16502-16513.

	Best regards,

	Serghey.

****************************************************************************************
Serghey I. Kotelevskii,
Department of Theoretical Chemistry and Astrochemistry,
Research Institute for Chemistry,
Kharkiv VNKarazin National University,
Svobody Square 4,
UA-61077 Kharkiv, Ukraine



Hi,
     What is the cheapest method of producing reliable IR stretching
frequencies computationally i.e. which represents the best compromise
between cost and accuracy. I know these calculations can be performed
semi-empirically but I am not sure how accurate the results are.
Cheers,
            Paul
p.smith@student.umist.ac.uk