Hi Manjunath Wari,
I'll suggest that you to use all the processors present in your CPU
(eg. for quadcore system you can use %nprocshared=4 as the first line
of your input). And if you are running parallel then use lindaworkers
to call several (available) nodes for your job. It will surely
increase the speed of your calculations. %nprocshared keyword can be
used for both serial and parallel jobs.
Hope it will help.
With best regards,
Mehboob
On Tue, Jan 29, 2013 at 7:44 PM, Gkourmpis, Thomas
Thomas.Gkourmpis,borealisgroup.com <http://borealisgroup.com>
<owner-chemistry.:.ccl.net <mailto:owner-chemistry.:.ccl.net>> wrote:
James what you are asking is impossible to answer as it depends on
a number of parameters like the type of computer you use, the size
of your system and the level of accuracy (theory and/or basis set)
you want your results to have.
Traditionally for the same system and basis set HF is faster than
DFT and DFT is faster than CCSD (the later one coincidentally is
an expensive method)
I am sorry I cannot provide a more comprehensive answer but in
reality you are constrained by the parameters I have outlined above.
Regardless I hope this helps
Thomas
Thomas Gkourmpis
Researcher- Innovation & Technology
Borealis AB | SE-444 86 Stenungsund | Sweden
Tel. +46 303 205 576 | Mobile +46 766 378 106 | Fax +46 303 866 49
www.borealisgroup.com <http://www.borealisgroup.com/>| 556078-6633
| Swedish Companies Registration Office
thomas.gkourmpis]-[borealisgroup.com
<mailto:thomas.gkourmpis]-[borealisgroup.com>
___________________________________
Borealis - Shaping the Future with Plastics
*From:*owner-chemistry+thomas.gkourmpis==borealisgroup.com
<http://borealisgroup.com>]-[ccl.net <http://ccl.net>
[mailto:owner-chemistry+thomas.gkourmpis
<mailto:owner-chemistry%2Bthomas.gkourmpis>==borealisgroup.com
<http://borealisgroup.com>]-[ccl.net <http://ccl.net>] *On Behalf
Of *J D Whitfield jdwhitfield * gmail.com <http://gmail.com>
*Sent:* Monday, January 28, 2013 8:30 PM
*To:* Gkourmpis, Thomas
*Subject:* CCL:G: Facing difficulty in running g03 peogramm
What method are you using (e.g. HF, DFT, CCSD, etc)? This can
make a big difference in the run-time. Also what qualifies as a
"very long time"?
James
--
Dr. J. D. Whitfield
VCQ Postdoctoral Fellow
Vienna Center for Quantum Science and Technology
email: james.whitfield() univie.ac.at
<mailto:james.whitfield%28%29%20univie.ac.at>
web: homepage.univie.ac.at/james.whitfield
<http://homepage.univie.ac.at/james.whitfield>
On Mon, Jan 28, 2013 at 12:03 PM, Manjunath Ningappa Wari
sm5wari^^^gmail.com <http://gmail.com> <owner-chemistry() ccl.net
<mailto:owner-chemistry%28%29%20ccl.net>> wrote:
Sent to CCL by: "Manjunath Ningappa Wari" [sm5wari^^gmail.com
<http://gmail.com>]
I am calculating dipole moment in ground state for coumarine
molecules using
g03 program. It is taking very long time to calculate, so plz
suggest me how to
run faster the g03 program.
Thanking you
Manjunath Wari
Dept of Physics
Karnatk University
Dharwad.
e-mail: sm5wari_._gmail.com <http://gmail.com>
-= This is automatically added to each message by the mailing
script =-<br
E-mail to subscribers: CHEMISTRY() ccl.net
<mailto:CHEMISTRY%28%29%20ccl.net> or use:>
E-mail to administrators: CHEMISTRY-REQUEST() ccl.net
<mailto:CHEMISTRY-REQUEST%28%29%20ccl.net> or use>
Conferences:
http://server.ccl.net/chemistry/announcements/conferences/>
<br>
This Email and any files transmitted with it are confidential and
intended solely for the use of the individual or the entity to
whom it is addressed. If you have received this Email by error,
please notify the sender and delete the material from any storage
device. Borealis extends no warranties and makes no
representations as to the accuracy or completeness of the
information provided. It is the customer's responsibility to
inspect and test our products and technical advice in order to
satisfy itself as to the suitability of the products and technical
advice for the customer's particular purpose.