Hello Igors MihailovsThank you very much for your quick response.My output didn't terminate at all as per the input I provided. The geometry optimization does not converge as per the output I received. I didn't attach the output because it is really long but, I can show the last RMS Force and Displacement values. They are as follows:Item Value Threshold Converged?Maximum Force 0.030490 0.000450 NORMS Force 0.004366 0.000300 NOMaximum Displacement 0.372605 0.001800 NORMS Displacement 0.068999 0.001200 NOPredicted change in Energy=-6.415468D-03I am really thankful to you for the information you provided and will try to implement these techniques you told me in your previous email.Many Thanks and RegardsMallika KhareOn Thu, Aug 13, 2015 at 2:39 PM, Igors Mihailovs igors.mihailovs0-$-gmail.com <owner-chemistry:_:ccl.net> wrote:If it is geometry optimization that does not converge, You can probably increase MaxCycle of it, too, not just for SCF: Opt=(QST3,NoEigenTest,MaxCyc=2048). Also (and better), Opt=CalcFC might have helped – as You are requesting frequency calculation after the Opt, I assume You have resources for it. To use it, determine the step where Your calculation was most close to convergence, e. g. by using this command (stolen from "Exploring Chemistry with Electronic Structure Methods" by Foresman and Frisch):Dear Mallika,At which exactly part of calculation does it terminate? From Your output (which is just some last lines in file) nobody is able to determine whether this is SCF convergence failure or Geometry optimization failure, or something else...egrep 'out of|SCF Don|Converged| NO | YES | exceeded' your-output-file | grep -v '\\\\'and choosing the step with the least values; then adding to Your next input file keyword Geom=(Check,Step=N) where N is number of the best step. And Opt=(QST3,NoEigenTest,MaxCyc=2048,CalcFC).
It is also quite convenient to use XQC or YQC instead of QC nowadays: XQC is using quadratic algorithm only if regular SCF does not converge, whereas YQC is doing steepest descent following by regular SCF and only if the last fails does QC (however, YQC does not work in all cases, see, e. g. http://ccl.net/cgi-bin/ccl/message-new?2015+05+30+001). Sometimes SCF=Fermi helps, too. See http://www.ccl.net/cca/documents/dyoung/topics-orig/converge.html for further options.With best wishes,Igors Mihailovs (engineer)Institute of Solid State PhysicsUniversity of LatviaE-mail to subscribers: CHEMISTRY]^[ccl.net or use:
Sent to CCL by: "Mallika Khare" [mkhare- -mtu.edu]
Hello
I am struggling hard to get my job terminated. But, at this point I
couldn't figure out the reason for this error stated below. I checked by
increasing the maxcycle of SCF,increasing the memory and also checked my
checkpoint file but even then it is not optimized.(Using Geom=AllCheck
also makes no difference)
I would be very thankful if anyone can help me with this problem.
Thanks and Regards
Malllika Khare
mkhare[A]mtu.edu
Input
%nprocshared=12
%mem=30GB
%OldChk=filename.chk
%Chk=filename.chk
#p opt=(qst3,noeigentest) freq oniom(b3lyp/3-21+g*:b3lyp/sto-3g*:pm3)
scf=(qc,tight,maxcycle=6500)
geom=connectivity
Output
Error termination request processed by link 9999.
Error termination via Lnk1e in /share/apps/gaussian/D01/g09/l9999.exe at
Wed Aug 12 09:49:37 2015.
Job cpu time: 3 days 5 hours 47 minutes 0.4 seconds.
File lengths (MBytes): RWF= 150 Int= 0 D2E= 0 Chk= 70
Scr= 2
Error: segmentation violation
rax 0000000000000000, rbx ffffffffffffffff, rcx ffffffffffffffff
rdx 000000000002a8ac, rsp 00007fffffffa168, rbp 00007fffffffa6e0
rsi 000000000000000b, rdi 000000000002a8ac, r8 00002aaaaaaaf620
r9 0000000000000000, r10 00007fffffff9ef0, r11 0000000000000202
r12 0000000000000000, r13 0000000000000000, r14 00007fffffffa728
r15 00000000000003e6
--- traceback not available
-= This is automatically added to each message by the mailing script =-
http://www.ccl.net/cgi-bin/ccl/send_ccl_message
E-mail to administrators: CHEMISTRY-REQUEST]^[ccl.net or use
http://www.ccl.net/cgi-bin/ccl/send_ccl_message
Subscribe/Unsubscribe:
http://www.ccl.net/chemistry/sub_unsub.shtml
Before posting, check wait time at: http://www.ccl.net
Job: http://www.ccl.net/jobs
Conferences: http://server.ccl.net/chemistry/announcements/conferences/
Search Messages: http://www.ccl.net/chemistry/searchccl/index.shtml
http://www.ccl.net/spammers.txt
RTFI: http://www.ccl.net/chemistry/aboutccl/instructions/