Dear Netters,

Please help settle a small controversy.  For a particular molecular
mechanics calculation, I derived partial atomic charges from bond
dipole moment measurements made in nonpolar solvent.  I then ran
molecular mechanics calculations using an in vacuo dielectric constant
of 1.00.  A colleague argues that I must use a dielectric constant
appropriate to the nonpolar solvent from which the charges were
derived (e.g., 2-3).  It seems to me that the charges already embody
the effect of the nonpolar solvent's dielectric constant, and so using
the in vacuo value of 1.00 is okay and perhaps preferred.  Stated another
way, it seems to me that using these charges AND the dielectric of 2-3
would count the effect of the nonpolar solvent twice.

Any opinions on this matter are appreciated.

Thanks ...

Bill Welsh
Dept. of Chemistry
Univ. of Missouri-St. Louis
 



Similar Messages
08/04/1995:  Re:  CCL:Question about Electrostatics in Molecular Mechanics
08/04/1995:  Re: CCL:Question about Electrostatics in Molecular Mechanics
08/04/1995:  Re: Question about Electrostatics in Molecular Mechanics
08/04/1995:  Re: CCL:Question about Electrostatics in Molecular Mechanics
09/01/1995:  Questions re dielec. const. & conformers
09/01/1995:  Re:  CCL:M:Questions re dielec. const. & conformers
01/20/1997:  Summary:  Removing charges for an MD simulation
07/07/1995:  Summary: Opinions on the quantum charges
05/21/1999:  Solvation and TS's
09/27/1994:  Charges


Raw Message Text